$3,395.00
$3,195.00
Includes: Monopolar Footswitch   Instant Response™ Technology Instant Response™ technology provides surgeons with improved performance at lower power settings, minimizing the risk of tissue damage and neuromuscular stimulation, and decreasing...
{{ product.metafields.CustomInfo.Condition }}
{{ product.metafields.CustomInfo.Lead }}
{{ product.metafields.CustomInfo.Warranty }}
{{ product.metafields.CustomInfo.Shipping }}
{% for t in product.tags %} {% if t contains 'refurbished' %} {% endif %} {% endfor %}
Sku: FX
Vendor: Valleylab
Includes: Monopolar Footswitch

 

Instant Response™ Technology

Instant Response™ technology provides surgeons with improved performance at lower power settings, minimizing the risk of tissue damage and neuromuscular stimulation, and decreasing the need to "turn up the generator."

A Smoother Cut Through All Tissue Types

The Force FX™ generator adjusts automatically, responding to tissue changes, maintaining power delivery, and minimizing drag.

Added Safety and Reliability Minimizes Electrosurgical Risks

Capacitive coupling is reduced by 30-50% when using Instant Response™ technology. This reduction is achieved by limiting the RMS voltage and the high frequency harmonics. Lower voltage means less neuromuscular stimulation and more precise delivery of energy to reduce collateral damage.

What is Instant Response™ Technology?

Instant Response™ technology features an advanced feedback system that recognizes changes in tissue 200 times per second, and adjusts voltage and current accordingly to maintain appropriate power. This unique capability differentiates Instant Response™ generators from any other, as shown by their high power efficiency rating (PER). That's smart™ generator technology.

PER indicates the ability of a generator to accurately deliver the selected power into a wide range of tissue types. With a PER of 98, the Force FX™ generator provides a consistent surgical effect and has a higher PER than any other electrosurgical generator.

Instant Response™ Technology provides consistent power through different tissue types.

The Force FX™ generator provides surgeons with the advantage of accurately delivering the selected power setting, even through resistant tissue.

When a conventional generator encounters tissue changes, both power delivery and cutting efficiency are reduced. This means that higher power settings are required in order to cut through all types of tissue. With higher power settings, more energy is delivered, and tissue damage increases.

Features

  • Instant Response™ technology ensures that the power delivered remains virtually constant, regardless of the tissue type
  • Improved performance at lower power settings minimizes the risk of tissue damage and neuromuscular stimulation
  • Three internal microcontrollers reduce system reaction time and increase the system's processing speed
  • Spray coagulation voltage of no more than 9000 volts peak-to-peak output for broad, but superficial coagulation with limited capacitive coupling
  • A Power Efficiency Rating (PER) of approximately 98 for accurate and consistent cut performance
  • Three cut modes, all controlled by Instant Response™ technology, offer surgeons a variety of choices:
    • Low Cut for delicate tissue or laparoscopic cases
    • Pure Cut for a clean, precise cut
    • Blend for cutting with hemostasis
  • Four coag modes:
    • Desiccate for low voltage contact coagulation suitable in laparoscopic and delicate tissue work
    • Fulgurate (high crest factor) for efficient noncontact coagulation in most applications
    • Fulgurate (low crest factor) for lower voltage coagulation requirements
    • Spray for coagulating large tissue areas with superficial depth of necrosis
  • Three bipolar modes:
    • Precise, Standard, and Macrobipolar are controlled by the Instant Response™ system
    • Precise and Standard setting utilize low voltage to prevent sparking
  • Versatile system that is uniquely compatible with other devices, including:
    • Force Argon™ II and Force GSU™ argon coagulation system
    • CUSA EXcel™ and CUSA™ 200 ultrasonic surgical aspirators
    • OptiMumm™ smoke evacuator, through a direct cable link
    • Valleylab VLCM bipolar current monitor
  • Compatible with and used as the electrosurgical energy source for:
    • Dyonics* Control RF arthroscopic ablation system
    • Dyonics* Electroblade™ rotary resection system
    • Cook Vascular Perfecta™ EDS pacemaker lead extraction system
  • Compatible with, and the exclusive electrosurgical generator for, the Computer Motion Hermes™ Voice Command System

* Trademark of Smith & Nephew

 

user manual

For new products, please refer to the manufacturer's website for details. Below is Victori Medical's Limited Warranty information:

This product has been refurbished and tested to the highest quality standards by Victori Medical, LLC. This Limited Warranty offered by Victori Medical, LLC covers defects in material or workmanship. This warranty extends to the original purchaser only and is nontransferable. The warranty begins the day the equipment is received. Please inspect your item(s) upon delivery. Any unauthorized service providers working on our equipment within the warranty period will void the warranty!

Victori Medical, LLC warrants this product against defects in material or workmanship as follows: A. Victori Medical, LLC will replace at no charge for parts only or, at its option,replace any product or part of the product that proves defective because of improper workmanship and/or material, under normal installation, use, service and maintenance. If Victori Medical, LLC is unable to provide a replacement and repair is not practical or cannot be made in a timely fashion, Victori Medical, LLC may elect to refund the purchase price in exchange for the return of the product.

Our warranty periods are 90 days parts and labor from the documented date of receipt. Extended warranties (up to 1 year from date of purchase) are available.

Our warranties do not cover any problem that is caused by: A. Conditions, malfunctions or damage not resulting from defects in material or workmanship. B. Conditions, malfunctions or damage resulting from (1) normal wear and tear, improper installation, improper maintenance, misuse, abuse, negligence, accident or alteration.

Our limited warranties are void if a product is returned with removed, damaged or tampered labels or any alterations (including removal of any component or external cover).

Victori Medical, LLC will not provide any warranty coverage unless claims are made in compliance with all terms of the controlling warranty statement included with your product and you follow proper return procedure. To request warranty service, you will need to provide: 1. The invoice or other evidence of the date and place of purchase. 2. A description of the problem. 3. Contact our Customer Service Department to receive a Return Authorization Number (RMA#)

When warranty service is completed, any repaired or replacement product or part will be returned to you postage prepaid.

Victori Medical, LLC SHALL NOT BE LIABLE TO THE PURCHASER OR ANY OTHER PERSON FOR ANY INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES, ARISING OUT OF BREACH OF THIS WARRANTY OR ANY IMPLIED WARRANTY (INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY).

The laws of the State of Illinois, USA, govern our warranties. It gives you specific legal rights, and you mayalso have other rights that vary from state to state. Our warranties do not affect any additional rights consumers have under laws in their jurisdictions governing the sale of consumer goods. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the limitations or exclusions in our warranty statements may not apply. You may be required by law to give us a reasonable opportunity to correct or cure any failure to comply before you can bring any action in court against us under the Magnuson-Moss Warranty Act.

RETURN POLICY

  • Damaged freight needs to be reported within 24 hours to file a claim.
  • No merchandise may be returned without prior written authorization by Victori Medical.
  • No NEW merchandise may be returned unless authorization from manufacturer which could result in a restocking fee or no return at all, and customer is responsible for shipping expenses.
  • Return period for products is thirty (30) days from delivery or otherwise agreed upon.
  • Victori Medical will test returned products returned and can impose a customer fee if the customer misrepresents the condition of the product.

CREDIT AND RETURN SHIPPING GUIDELINES

  • Order cancellations (after 24 hours) and returns are charged a 25% restocking fee.
  • If the credit or return is Victori Medical's Error, then 100% credit including shipping expenses will be credited.
  • Unused goods in original packaging may receive an 75% credit, and customer is responsible for shipping expenses both ways unless otherwise agreed upon.
  • Damaged goods will receive credit dependent on the condition of the product, and customer is responsible for shipping expenses.
  • No credit will be issued if the item is non-returnable, such as a new product, custom or special order, or in the case that the item is damaged due to improper handling/packaging by the customer.

FREE SHIPPING ON $100 MINIMUM ORDER RESTRICTIONS

  • Free shipping applies to qualifying orders over $100 or more
  • Because of freight charges, we cannot offer free shipping on hospital beds, exam tables, procedure chairs, stretchers, C-Arms, and surgical tables
  • Free shipping includes any FedEx, UPS, & USPS shipping but excludes any LTL freight delivery, liftgate service delivery, inside delivery, and white glove service.
  • Free shipping includes all 48 contiguous US states, but excludes Hawaii and Alaska
  • WILL NOT DELIVER INSIDE TO RESIDENTIAL HOMES. YOU WILL NEED TO HAVE YOUR OWN MOVING COMPANY OR HELP. IF NOT, THE ITEM WILL BE DELIVERED TO THE DRIVEWAY.

Shipping Charges:

Customers are responsible for making sure items can be delivered into or outside of their facility without issue. For example, can a 53’ foot truck access your building? Failure to accommodate delivery can result in items not being delivered, additional fees, or return of equipment.

Basic Shipping Charge is for dock to dock shipping and/or liftgate service shipping. The items shipping dock to dock and/or liftgate are skidded/palletized items. It doesn’t not include inside delivery.

Residential shipping charge is for customer’s needing delivery in a residential area.

Inside delivery is for customer’s needing their purchase delivered inside the building. The item(s) will be delivered into the lobby only. They not be delivered into rooms/suites, elevators, or stairs.

Customers are responsible for disposing of packing materials.

If you are needing white glove delivery, please contact us directly at orders@tasimed.com.